Substructure design
HydroCon
2017-02-06T02:28:13+00:00

Download illustration as pdf
|
|
| ITEM |
RECOMMENDATIONS |
| Permeable pavers |
HydroSTON vehicle pavers (HydroSTON 80) supplied by HydroCon. |
| Paving joints |
HydroCon recommends that HydroSTON 80 be laid in herringbone pattern to maximise interlocking. Pavers can be butted together without gap joints. |
| Bedding |
2-5 mm graded or 5 mm single size low fines crushed rock preferably basalt or equivalent compacted to 30 mm depth. Alternative bedding material: minus 4.75 mm washed recycled glass (GlassSand). |
| Geotextile |
Nonwoven geotextile hydraulic conductivity min. 3600 mm/hr eg Geofirma 200B Bidim A24 or equiv. |
| Base course |
5-20 mm low fines crushed rock preferably basalt or equivalent compacted in layers to 150 mm depth (100 mm min.). |
|
Alternative base course material for easier compaction and greater stability: 0-2 mm washed sand (30-50% sand <3-5% passing 0.075 mm) / 2-20 mm aggregate (50-70 % low fines aggregate). |
|
|
| Water harvesting or external discharge applications |
|
| Sub-base (if required for increased water storage) |
20-40 mm low fines crushed rock. |
| Underdrain |
DN90 slotted PVC pipe eg IPLEX WPS090SL. |
| Liner |
0.75 mm linear low density polyethylene (LLDPE) 1.5 mm high density polyethylene (HDPE). Check with supplier on appropriate product for application. |
| Liner protector |
Woven geotextile. Check with supplier on appropriate product for application. |